Floton S20 Advanced Non-Invasive Ventilation

Adaptive Triggering  Technology (ATT)  tracks  every  breath and monitors  the different stages   of   the respiration cycle utilizing an Advanced Leak Calculation Algorithm that ensures reduced work  of  breathing (WOB) whilst providing the patient with effective and comfortable treatment.

Curative Medical Inc., USA  introduces new Floton Non-Invasive Bi Level  Positive   Airway Pressure systems for the treatment of Respiratory insufficiency including COPD  and Obstructive Sleep Apnea.

Compact, Lightweight and Quiet the Floton BiLevel Series understands that every breath is different    using the Advanced Adaptive Triggering Technology (ATT) designed to effortlessly synchronize with the natural breathing of the patient.

The New Cutting Edge Technology incorporates the measurement of the pressure directly at the mask level through a specially designed Hose Pipe.

This technology makes it  possible  for accurate leak  management and enhances the sensitivity of the  machine  to  detect  extremely low patient  effort.

Floton ST series ventilators have advanced  modes of BiLevel  Ventilation  including  CPAP, S,  ST,  T, APCV.  The new APCV (Assisted Pressure Control Ventilation) mode  allows the patient to trigger an inspiration  even as it follows  the Time cycle and backup  breath rate decided by the physician.

One of the main reasons for machine fault is the seepage of water from the integrated humidifier into the machine during transport or shifting. In Floton BiLevel Systems, the disconnection of the integrated humidifier connecting pipe isolates the flow generator from the humidifier.

 

Floton Specifications

Pressure Range BiLevel – S20 : 4cmH20 – 20cmH20
Pressure Measurement Mask Pressure
Ramp Time 0-60min adjustable 1min/step
BPM* 5 to 50 Breaths Per Minute
I/E%* 10% to 80%
Ventilation Mode* 2 modes:  SPONTANEOUS AND CPAP
I-Slop 6 levels. From 100msec to 600msec
Expiratory Cycling E-Sens : 6 Levels
Inspiration Triggering I-Sens : 6 Levels, Adaptive Triggering /
Technology (ATT)
Tidal Volume 50 to 3000ml
Noise (10cm H2O )  <28dB (A)
Dimensions 180mm x 210mm x 105mm
Weight 1.2kg (1.55kg with humidifier)
Automatic Altitude Compensation 700hPa ~ 1060hPa
Mask On / Off Detection Automatic Start/Stop on breath detection
Alarms  Power Failure, Low minute ventilation,Low Tidal Volume, Apnea, High Pressure
Power Supply 100-240 VAC, 50/60 Hz, 24DV, 2.5 A max.
Protection against shock / Water ingress Class II, Type B applied part / IPXO
Electromagnetic compatibility EN 60601-1-2
Certification CE 0123
Relative Humidity 10% ~ 93% (Non-condensing)
Humidifier** Heated, Integrated, 250ml, 44 C
Data Recording 365 days of data storage, Respiratory Events,
Trends of Pressure leak and Respiratory Rate.
* : Feature not available in Floton S20** : Humidifier Optional